NDI EVALUATION OF LOCAL OXIDIZED C C-SIC SPECIMENS/

Citation
Rm. Aoki et al., NDI EVALUATION OF LOCAL OXIDIZED C C-SIC SPECIMENS/, Insight (Northampton), 40(10), 1998, pp. 706-711
Citations number
11
Categorie Soggetti
Instument & Instrumentation","Materials Science, Characterization & Testing
Journal title
ISSN journal
13542575
Volume
40
Issue
10
Year of publication
1998
Pages
706 - 711
Database
ISI
SICI code
1354-2575(1998)40:10<706:NEOLOC>2.0.ZU;2-I
Abstract
Problems related to the experimental non-destructive evaluation (NDE) the fibre-reinforced ceramic material C/C-SiC fabric are discussed. Th e detectability and the analysis by means of NDE is described for dama ged caused by localised oxidation. The NDE methods used in this invest igation were mechanical vibration, pulse thermography, ultrasonics (US ). and X-ray transmission. Quantitative evaluation of these methods sh ows that a good correlation between frequency change in the mechanical vibration ann attenuation in US C-scan tl ns obtained We also found t hat the damage affects thermal diffusivity.