The use of double-inlet mode in the pulse tube cooler opens up a possi
bility of DC gas flow circulating around the regenerator and pulse tub
e. Numerical analysis shows that effects of DC flow in a single-stage
pulse tube cooler are different in some aspects from that in a 4 K pur
se tube cooler. For highest cooler efficiency, DC flow should be compe
nsated to a small value, i.e. DC flow over average AC flow at regenera
tor inlet should be in the range -0.0013 to +0.00016. Dual valves with
reversed asymmetric geometries were used for the double-inlet bypass
to control the DC flow in this paper. The experiment, performed in a s
ingle-stage double-inlet pulse tube cooler, verified that the cooler p
erformance can be significantly improved by precisely controlling the
DC flow. (C) 1998 Elsevier Science Ltd. All rights reserved.