A new ion-exclusion HPLC procedure for the determination of organic ac
ids in vinegars under isocratic elution was developed. Optimum experim
ental conditions for pH of the eluent, column temperature and mobile p
hase flow-rate were estimated from a factorial design. The method was
successfully validated and enables the reliable separation of major or
ganic acids in wine vinegars (i.e. tartaric, citric, malic, lactic and
acetic acid) in about 25 min. It was applied to the analysis of diffe
rent vinegar samples. (C) 1998 Elsevier Science B.V. All rights reserv
ed.