MICRO COOLING SYSTEMS FOR HIGH-DENSITY PACKAGING

Authors
Citation
B. Gromoll, MICRO COOLING SYSTEMS FOR HIGH-DENSITY PACKAGING, Revue generale de thermique, 37(9), 1998, pp. 781-787
Citations number
11
Categorie Soggetti
Engineering, Mechanical",Thermodynamics
Journal title
ISSN journal
00353159
Volume
37
Issue
9
Year of publication
1998
Pages
781 - 787
Database
ISI
SICI code
0035-3159(1998)37:9<781:MCSFHP>2.0.ZU;2-5
Abstract
Future 3D electronics packaging systems will require micro cooling sys tems that can be integrated and permit the continued use of air as a c oolant. To achieve this, new types of silicon micro heat exchangers we re made using an anisotropic etching process. Various heat exchanger c onfigurations and sizes were made using sandwich and stacking techniqu es. They can be used either as a heat exchanger for direct cooling wit h compressed air or as a heat pipe and thermosyphon for indirect cooli ng with fan-blown air. The performance characteristics of the various cooling systems are stated. The micro-heat-pipe can be used for power loss densities of up to 3 W.cm(-2), the direct air cooling up to 15 W. cm(-2) and the thermosyphon up to 25 W.cm(-2) Cooling performances are achieved that are otherwise only possible with liquid cooling. The pr actical application of the micro cooling system is demonstrated using the example of the Pentium processor. With a power loss of 15 W, the h igh-performance micro cooling system is able to limit the increase in operating temperature to 15K. The volume of the micro heat exchanger i s 2.5 cm(3) and therefore considerably smaller than that of standard h eat sinks. (C) Elsevier, Paris.