Hs. Bai et al., STUDY ON ANALYSIS OF SM-153-EDTMP STABILITY IN-VITRO AND VIVO BY HPLC, Journal of radioanalytical and nuclear chemistry, 236(1-2), 1998, pp. 87-95
The behavior of Sm-153-EDTMP in vitro and vivo is analyzed by the size
exclusion HPLC. The experimental results show that EDTMP amounts have
an obvious effect on the stability in vitro and uptake of Sm-153-EDTM
P in the liver. HPLC analysis of urine sample indicates that Sm-153-ED
TMP is excreted in the original form. The behavior in vivo of Sm-153-E
DTMP containing 4 mu g is similar to that of Sm-153-EDTMP containing 5
0 mu g EDTMP at I h post-injection.