UPGRADING RECYCLED HDPE BY RHEOMETER-CONTROLLED CROSS-LINKING

Citation
A. Pillo et al., UPGRADING RECYCLED HDPE BY RHEOMETER-CONTROLLED CROSS-LINKING, International polymer processing, 12(1), 1997, pp. 4-10
Citations number
7
Categorie Soggetti
Engineering, Chemical","Polymer Sciences
ISSN journal
0930777X
Volume
12
Issue
1
Year of publication
1997
Pages
4 - 10
Database
ISI
SICI code
0930-777X(1997)12:1<4:URHBRC>2.0.ZU;2-V
Abstract
An in-line rheometer previously described was evaluated for use in the upgrading of post-consumer, recycled HDPE. Feed resin of variable mel t index was brought to a preset, uniform viscosity by peroxide induced crosslinking in a twin-screw extruder. Closed loop control was demons trated using the rheometer as a viscosity sensor. Set-point tracking w as achieved using PID-IMC, Dahlin and minimum variance (MV) controller s. The Dahlin controller showed the best load rejection.