T. Erbe et al., X-RAY CONTRAST-MEDIA - A SOURCE OF THE AOX LOAD IN-HOSPITAL WASTE-WATER, RoFo. Fortschritte auf dem Gebiete der Rontgenstrahlen und der neuenbildgebenden Verfahren, 169(4), 1998, pp. 420-423
Citations number
15
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
Journal title
RoFo. Fortschritte auf dem Gebiete der Rontgenstrahlen und der neuenbildgebenden Verfahren
Purpose: To identify the sources for the exceeding of the upper limit
of the AOX (adsorbable organic halogen, X = Cl, Br, I) in hospital was
te-water and to estimate the contribution of hospital waste-water to t
he AOX of municipal waste-water. Methods: For several hospitals with d
ifferent medical directions, the expected AOX-concentration, as far as
it is caused by iodine contrast media, was ascertained by the contras
t media consumption and the water consumption. The results were compar
ed with the measured AOX concentrations. Results: The AOX-concentratio
n of hospital waste-water varies between 0.41 mg/l and 0.94 mg/l. Conc
lusion: As a source of AOX iodine contrast media have been identified
and may contribute considerably to the AOX. Hospitals with a radiologi
cal department may exceed the upper limit of the AOX which has to be o
bserved in German municipal waste-water.