Three-dimensional radiation shielding analysis around a large helical
device (LHD) has been performed in order to confirm the margin of the
present shielding design and to provide more detail information on a r
adiation environment for machine design and operation planning. Calcul
ations were carried out using three-dimensional Sn code TORT and 25 gr
oup cross-section data based on the JENDL-3 library, and shielding cha
racteristic were examined. Consequently, the radiation leakage effect
due to the helical-shaped plasma and coils is necessary to be consider
ed in the evaluation of the radiation flux distribution and its relate
d evaluation: nuclear heat generation inside the cryostat. The present
design method based on two-dimensional calculations was compared with
three-dimensional calculations, and turned out to be an appropriate m
ethod with a suitable conservativeness with regard to the leakage sour
ce term calculation. (C) 1998 Elsevier Science S.A. All rights reserve
d.