Cc. Wu et al., STAPLE AUGMENTATION TO TREAT A HUMERAL NONUNION AFTER FAILED SEIDEL LOCKED NAILING, Archives of orthopaedic and trauma surgery, 118(1-2), 1998, pp. 42-44
Seidel locked nailing has been successfully used to treat a humeral sh
aft fracture or nonunion. However, if union fails despite this treatme
nt, the next approach to try has not been well defined. We, therefore,
developed a technique using a staple to enforce the local stability w
ithout removing the failed nail. The technique was very simple, and th
e outcome was always satisfactory.