Nj. Fentiman et al., A NOVEL PROFILED BLADE IMPELLER FOR HOMOGENIZATION OF MISCIBLE LIQUIDS IN STIRRED VESSELS, Chemical engineering research & design, 76(A7), 1998, pp. 835-842
A novel axial flow impeller with profiled blades has been designed and
manufactured using CAD/CAM techniques. The impeller was of diameter D
= T/3 and located at a clearance of C = T/3. Its mixing characteristi
cs were measured in two vessels of 100 mm and 290 mm diameter. The imp
eller power number is 0.22 and its mixing mumber is 48. The flow numbe
r and the circulation flow number were determined by LDA measurements
to be 0.52 and 1.00 respectively. Comparisons with other axial flow im
pellers are made and it is shown that the impeller can provide a very
efficient means for the homogenization of liquids in stirred vessels.