Y. Nohara et al., AUTOMATIC SYSTEM FOR THE ASSAY OF GUANIDINO COMPOUNDS TO ASSESS UREMIC STATUS AND EFFECT OF HEMODIALYSIS, Chemical and Pharmaceutical Bulletin, 46(11), 1998, pp. 1844-1845
An automated HPLC system coupled with fluorometry Has established for
the sensitive, rapid, and accurate assay of serum guanidines. Naturall
y fluorescent materials characteristic of the sera of uremic patients
(uremic fluorescences) which interfere with the assay were removed sim
ultaneously with deproteinization, Application of this method revealed
that the uremic patients who are capable of excreting: urine under he
modialysis therapy show low serum guanidinosuccinic acid levels. The i
nterval between hemodialysis sessions in one of these patients was pro
longed while monitoring guanidinosuccinic acid level using the present
method without any hazardous effect.