R. Boni et al., DA-PHI-NE ACCUMULATOR RING COUPLING IMPEDANCE MEASUREMENTS, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 418(2-3), 1998, pp. 241-248
We discuss the results of the bunch lengthening and synchronous phase
shift measurements performed during the commissioning of the DA Phi NE
accumulator ring and aimed to estimate the machine longitudinal coupl
ing impedance. The dependence of the bunch length on the average curre
nt measured experimentally is in a good agreement with that predicted
numerically. The low frequency machine impedance is estimated to be 3.
55 Omega. It was also found that the parasitic beam power losses and t
he bunch shape distortion depend strongly on the actual RF cavity High
er Order Mode (HOM) positions with respect to the beam power spectrum
lines. In particular, we observed that the effect of the HOMs can be m
inimized by raising the cavity temperature to 37 degrees C. (C) 1998 E
lsevier Science B.V. All rights reserved.