Determination of water soluble trace gases in ambient air by condenser-type diffusion denuder coupled ion chromatography

Citation
Ih. Chang et al., Determination of water soluble trace gases in ambient air by condenser-type diffusion denuder coupled ion chromatography, B KOR CHEM, 20(3), 1999, pp. 329-332
Citations number
13
Categorie Soggetti
Chemistry
Journal title
BULLETIN OF THE KOREAN CHEMICAL SOCIETY
ISSN journal
02532964 → ACNP
Volume
20
Issue
3
Year of publication
1999
Pages
329 - 332
Database
ISI
SICI code
0253-2964(19990320)20:3<329:DOWSTG>2.0.ZU;2-Z
Abstract
An automated method is developed for simultaneous determination of water so luble eases at parts per trillion level in the environmental air. The metho d involves temperature-humidity control of sample air using a thermostated humidifier, collection of analyte gases by condenser-type effluent diffusio n denuder and subsequent effluent analysis by ion chromatography. The detec tion Limits (3 sigma) of the method for CH3COOH, HNO2 and SO2 gases are 0.0 22, 0.019 and 0.009 ppbv, respectively. The precisions range from 0.3 to 3. 0% RSD. The method has been successfully applied to urban air analysis and some results for nitrous acid and SOx in Seoul air are presented.