TOF measurement in RIBLL

Citation
Jx. Li et al., TOF measurement in RIBLL, HIGH EN P N, 23(3), 1999, pp. 231-236
Citations number
5
Categorie Soggetti
Physics
Journal title
HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION
ISSN journal
02543052 → ACNP
Volume
23
Issue
3
Year of publication
1999
Pages
231 - 236
Database
ISI
SICI code
0254-3052(199903)23:3<231:TMIR>2.0.ZU;2-L
Abstract
In this paper we present a timing pickup detector used at Radioactive Ion B eam Line in Lanzhou (RIBLL). It has low detection threshold and is radiatio n-resistant The photons induced by radioactive beam ions passing through a thin plastic-scintillator foil, emit from the foil center corresponding to one focus point of a aluminum ellipsoidal mirror and are reflected to anoth er focus point at which the cathode of a photomultiplier tube locates. The readout pulse signals were sent into a CAMAC' s TDC module. A time resoluti on of about 140ps is achieved and the counting rate up to 10(8)pps is allow ed.