Vy. Petrovskii, Use of conducting composites based on Si3N4 in broadband electric heaters.II. Energy characteristics of an all-ceramic heater, POWD MET ME, 37(5-6), 1998, pp. 291-297
The most important energy parameters of any heater are [1] the unit surface
load (power consumed per unit of heater surface), efficiency, and the dura
bility of the filament (service life, safe life). In this article, we exami
ne the main energy characteristics of a new all-ceramic heater and compare
them to the parameters of the electric heaters and infrared radiators most
commonly used in industry.