R. Tello et al., MR HYSTEROGRAPHY USING AXIAL LONG TR IMAGING WITH 3-DIMENSIONAL PROJECTIONS OF THE UTERUS, Computerized medical imaging and graphics, 21(2), 1997, pp. 117-123
A rapid screening technique for the presentation of uterine cavity ana
tomy obtained with MR is described, MR hysterographic (MRHG) images we
re generated and evaluated for uterine cavity abnormalities, Six patie
nts referred for MRI evaluation of the uterus for infertility had an M
RI using a pelvic phased array coil with axial 3 mm interleaved fast s
pin echo images (TR 9000 ms, TE 288 ms with fat saturation) processed
using maximum intensity projection algorithms to construct MRHG images
, Using the conventional MR sequence as the gold standard the MRHG ima
ges were evaluated by two reviewers and accuracy calculated, MRHG took
less than 3 min, demonstrated the correct diagnosis in all with a qua
lity score of diagnostic to optimal, and with excellent interobserver
agreement (kappa 0.9). (C) 1997 Elsevier Science Ltd.