MR HYSTEROGRAPHY USING AXIAL LONG TR IMAGING WITH 3-DIMENSIONAL PROJECTIONS OF THE UTERUS

Citation
R. Tello et al., MR HYSTEROGRAPHY USING AXIAL LONG TR IMAGING WITH 3-DIMENSIONAL PROJECTIONS OF THE UTERUS, Computerized medical imaging and graphics, 21(2), 1997, pp. 117-123
Citations number
13
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
ISSN journal
08956111
Volume
21
Issue
2
Year of publication
1997
Pages
117 - 123
Database
ISI
SICI code
0895-6111(1997)21:2<117:MHUALT>2.0.ZU;2-8
Abstract
A rapid screening technique for the presentation of uterine cavity ana tomy obtained with MR is described, MR hysterographic (MRHG) images we re generated and evaluated for uterine cavity abnormalities, Six patie nts referred for MRI evaluation of the uterus for infertility had an M RI using a pelvic phased array coil with axial 3 mm interleaved fast s pin echo images (TR 9000 ms, TE 288 ms with fat saturation) processed using maximum intensity projection algorithms to construct MRHG images , Using the conventional MR sequence as the gold standard the MRHG ima ges were evaluated by two reviewers and accuracy calculated, MRHG took less than 3 min, demonstrated the correct diagnosis in all with a qua lity score of diagnostic to optimal, and with excellent interobserver agreement (kappa 0.9). (C) 1997 Elsevier Science Ltd.