As a part of the plasma diagnostic system for the Hanbit device, various mi
crowave plasma diagnostic systems have been designed and developed from the
initial stage of the Hanbit project. These include the interferometer, ref
lectometer, and electron cyclotron emission radiometer. In this work, we pr
esent the current activities related to the development of the microwave di
agnostic systems. The brief descriptions of each system are as follows. The
probing wave frequency of the interferometer is 94 GHz. Two types of inter
ferometer have been developed. One is a conventional heterodyne-type interf
erometer with two microwave sources (94 GHz, 94.2 GHz Gunn oscillators). Th
e other system uses a heterodyne-type phase detection method with one micro
wave source (94 GHz, Gunn oscillator) and a single sideband upconverter. Fo
r the plasma density profile measurements, an FM-CW reflectometer with a 7-
18 GHz YIG source will be installed at the Hanbit central cell. If the O-mo
de propagation is adopted, it can cover one half portion of the central cel
l plasma density profile under the density 5 x 10(12) cm(-3). A heterodyne
phase detection method is also used for this reflectometer with a single si
deband upconverter. (C) 1999 Elsevier Science S.A. All rights reserved.