GAS-CHROMATOGRAPHIC METHOD FOR PUTRESCINE AND CADAVERINE IN CANNED TUNA AND MAHIMAHI AND FLUOROMETRIC METHOD FOR HISTAMINE (MINOR MODIFICATION OF AOAC-OFFICIAL-METHOD-977.13) - COLLABORATIVE STUDY
Pl. Rogers et W. Staruszkiewicz, GAS-CHROMATOGRAPHIC METHOD FOR PUTRESCINE AND CADAVERINE IN CANNED TUNA AND MAHIMAHI AND FLUOROMETRIC METHOD FOR HISTAMINE (MINOR MODIFICATION OF AOAC-OFFICIAL-METHOD-977.13) - COLLABORATIVE STUDY, Journal of AOAC International, 80(3), 1997, pp. 591-602
A collaborative study was conducted to test a modification to the AOAC
fluorometric method for histamine (AOAC(R) Official Method 977.13) th
at substitutes 75% methanol as the extracting solvent. AII other steps
remain unchanged. The extracts prepared with 75% methanol were also u
sed to collaboratively test a gas chromatographic (GC) method for dete
rmination of putrescine and cadaverine in seafood. In the GC method, t
he extracted diamines are converted to fluorinated derivatives, the re
action mixtures are passed through solid-phase extraction columns, and
the derivatives are quantitated by electron capture GC after separati
on on an OV-225 column. Fourteen laboratories using the GC method for
putrescine and cadaverine and 16 laboratories using the fluorometric m
ethod for histamine analyzed 14 canned tuna and raw mahimahl (includin
g blind duplicates and a spike) containing 0.2-2.6 ppm putrescine, 0.6
-9.1 ppm cadaverine, and 0.6-154 ppm histamine, At the 5 ppm level, re
coveries ranged from 71 to 102% for putrescine and 77 to 112% for cada
verine; the respective repeatability relative standard deviations (RSD
r) were 5.2 and 15%, and the respective reproducibility relative stand
ard deviations (RSDR) were 8.8 and 18%, At the 50 ppm level, histamine
recoveries ranged from 84 to 125%, RSDr was 3.6%, and RSDR was 9.4%,
The GC method for determination of putrescine in canned tuna and cadav
erine in canned tuna and mahimahi has been adopted first action by AOA
C INTERNATIONAL, and the AOAC Official Method 977.13, Histamine in Sea
food, Fluorometric Method, has been modified.