Radiation damage effect on avalanche photodiodes

Citation
S. Baccaro et al., Radiation damage effect on avalanche photodiodes, NUCL INST A, 426(1), 1999, pp. 206-211
Citations number
9
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
426
Issue
1
Year of publication
1999
Pages
206 - 211
Database
ISI
SICI code
0168-9002(19990421)426:1<206:RDEOAP>2.0.ZU;2-0
Abstract
Avalanche photodiodes have been chosen as photon sensors for the electromag netic calorimeter of the CMS experiment at the LHC, These sensors should op erate in the 4 T magnetic field of the experiment. Because of the high neut ron radiation in the detector extensive studies have been done by the CMS c ollaboration on the APD neutron radiation damage. The characteristics of th ese devices after irradiation have been analyzed, with particular attention to the quantum efficiency and the dark current. The recovery of the radiat ion-induced dark current has been studied carefully at room temperature and at slightly lower and higher temperatures. The temperature dependence of t he annealing has been evaluated. (C) 1999 Elsevier Science B.V. All rights reserved.