Water sampler and flow measurement for runoff containing large sediment particles

Authors
Citation
Jv. Bonta, Water sampler and flow measurement for runoff containing large sediment particles, T ASAE, 42(1), 1999, pp. 107-114
Citations number
8
Categorie Soggetti
Agriculture/Agronomy
Journal title
TRANSACTIONS OF THE ASAE
ISSN journal
00012351 → ACNP
Volume
42
Issue
1
Year of publication
1999
Pages
107 - 114
Database
ISI
SICI code
0001-2351(199901/02)42:1<107:WSAFMF>2.0.ZU;2-S
Abstract
A flow-measuring and composite water-sampler system was needed for sampling sediment-laden flows containing large rock particlebs from strip-mine spoi l erosion plots. The median percentage of soil particle sizes greater than 16 mm of the greater-than 2 mm fraction was 25%. A modified drop-box weir w as used for measuring flows, and for providing a well-mixed water and sedim ent flow that could be sampled. A "diverter" composite sampler was designed to divert the entire flow from a waste position to a sample position, and precluded the need to subsample (split) the sampled flows. Indoor testing o f the sampler showed the sampler worked well with the modified drop-box wei r Field evaluation showed the sampler and drop-box weir worked well under n atural rainfall conditions. Recommendations for improvement in sampler and weir operation are given. Use of the sampler for other applications is also discussed.