Ub. Dorfler et al., A holographic method for the determination of all linear electrooptic coefficients applied to Ce-doped strontium-barium-niobate, APP PHYS B, 68(5), 1999, pp. 843-848
Using c- and a-cut plates of strontium-barium-niobate doped with 0.66 mol.%
cerium all nonzero components of the linear electrooptic tensor r(13), r(4
2), r(33) including the sign are determined from angular dependence of the
two-beam coupling coefficient Gamma using transmission and reflection geome
try of holographic recording. We found: r(13) = 56 pm/V, r(42) = 38 pm/V, a
nd r(33) = 333 pm/V. In addition we calculated the effective trap density N
-eff to be 2.2 x 10(17) cm(-3). The advantages of this method as well as th
e values obtained are discussed.