AUTOCALIBRATION OF HIGH-PRECISION DRIFT TUBES

Citation
C. Bacci et al., AUTOCALIBRATION OF HIGH-PRECISION DRIFT TUBES, Nuclear physics. B, 1997, pp. 311-316
Citations number
6
Categorie Soggetti
Physics, Nuclear
Journal title
ISSN journal
05503213
Year of publication
1997
Supplement
54B
Pages
311 - 316
Database
ISI
SICI code
0550-3213(1997):<311:AOHDT>2.0.ZU;2-7
Abstract
We present the results on MDT (monitored drift tubes) autocalibration studies obtained from the analisys of the data collected in Summer 199 5 on the H8B Muon Test Beam. In particular we studied the possibility of autocalibration of the MDT using four or three layers of tubes, and we compared the calibration obtained using a precise external tracker with the output of the autocalibration procedure. Results show the fe asibility of autocalibration with four and three tubes and the good ac curacy of the autocalibration procedure.