Oo. Omole et al., High-performance liquid chromatographic assay of (+/-)-lactic acid and itsenantiomers in calf serum, J CHROMAT B, 727(1-2), 1999, pp. 23-29
Two high-performance liquid chromatographic methods are described for the d
etermination of lactic acid and its enantiomers in calf serum. A 300 X 8.0
mm I.D. column packed with sulfonated styrene-divinylbenzene copolymer and
a 50 X 4.6 mm ODS column with N,N-dioctyl-L-alanine were used. UV detection
was at 205 and 236 nm for the non-chiral and chiral assays, respectively.
Both assays demonstrated excellent linear relationships between peak area r
atios and serum concentrations over a range of 0.5 to 20 mM, based on 100 m
u l bovine serum. Recovery was complete. Inter and within-batch bias and re
lative standard deviation were <15%. (C) 1999 Elsevier Science B.V. All rig
hts reserved.