A simplified design equation for evaluating the fire resistance of concrete
-filled circular and square hollow structural steel (HSS) columns is presen
ted. The equation is expressed in terms of various structural design parame
ters affecting the fire resistance, and hence can easily be integrated into
conventional structural design. This equation can be used to evaluate the
fire resistance of HSS columns filled with various types of concrete fillin
g. The use of the design equation greatly facilitates the calculation of th
e fire resistance of structural members on a performance basis. It also ena
bles the designer to find cost-effective solutions in providing the require
d fire resistance performance for structural members, simply by varying the
parameters of the members. The applicability of the proposed equation to a
design situation is illustrated through a numerical example. Practical gui
delines that can be implemented during the design and construction phase, a
nd which have beneficial effects on the fire resistance behaviour concrete-
filled of hollow steel columns, are also presented. Crown Copyright (C) 199
9 Published by Elsevier Science Ltd. All rights reserved.