O. Cakirer et al., The non-aqueous titrimetric assay of the selected anti-inflammatory agentsusing tetra-n-butylammonium hydroxide as titrant, J PHARM B, 20(1-2), 1999, pp. 19-26
A potentiometric titration method in non-aqueous media is proposed for the
determination of some commonly used anti-inflammatory agents. The direct po
tentiometric titration of three anti-inflammatory agents, namely mefenamic
acid, fenbufen and ibuprofen; and the indirect potentiometric titration of
diclofenac sodium was carried out in acetonitrile solvent using tetra-n-but
ylammonium hydroxide as titrant, at 25 degrees C and under a nitrogen atmos
phere. The method was found to be highly accurate and precise, having a rel
ative standard deviation of < 1.0% for all anti-inflammatory agents studied
. Also, it was shown that the method could be successfully applied to the a
ssay of commercial pharmaceuticals containing the above-mentioned anti-infl
ammatory agents. The validity of the method was tested by the recovery stud
ies of standard addition to pharmaceuticals and the results were found to b
e satisfactory. The proposed method is simple, rapid and sufficiently preci
se for quality control purposes. (C) 1999 Elsevier Science B.V. All rights
reserved.