Monitoring of oxytetracycline in ovine milk by high-performance liquid chromatography

Citation
G. Boatto et al., Monitoring of oxytetracycline in ovine milk by high-performance liquid chromatography, J PHARM B, 20(1-2), 1999, pp. 321-326
Citations number
18
Categorie Soggetti
Chemistry & Analysis
Journal title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
ISSN journal
07317085 → ACNP
Volume
20
Issue
1-2
Year of publication
1999
Pages
321 - 326
Database
ISI
SICI code
0731-7085(199906)20:1-2<321:MOOIOM>2.0.ZU;2-Z
Abstract
A method for 'in vivo' determination of the oxytetracyclin residues in ovin e milk at low levels is described. Two groups of Sardinian breed sheep were treated with a dose of oxytetracycline by intramammary infusion and intram uscular administration, respectively. Oxytetracycline residues in extracts obtained from a preliminary cleanup procedure, were detected by an isocrati c high-performance liquid chromatography (HPLC) method. Linear calibration plots were obtained over a large concentration range of 1 mg ml(-1)-10 ng m l(-1), with correlation coefficients higher than 0.996. Recoveries between 85.8 and 98.9% were obtained. Limit of detection (LOD) and limit of determi nation (LOQ) were 5.2 and 17.5 ng ml(-1), respectively. This method would b e useful for routine monitoring of oxytetracycline residues in ovine dairy milk. (C) 1999 Elsevier Science B.V. All rights reserved.