K. Hwang et al., Simultaneous analysis of free cyanide, phosphate, silver cyanide & buffer salts in silver plating solution by capillary ion analyzer, PLAT SURF F, 86(5), 1999, pp. 133-135
PSC (potassium silver cyanide), phosphate, free cyanide and berate componen
ts constituting silver plating solutions were simultaneously analyzed with
a capillary ion analyzer, using a chromate buffer at pH 11, Detection of ea
ch ion was achieved using on-column indirect photometry at 254 nm, The four
species were simultaneously analyzed. Simultaneous analysis is a needed an
d powerful technique for process chemical control in the metal finishing in
dustry.