Patellar tendon graft position after anterior cruciate ligament reconstruction - Interobserver variability on lateral radiographs

Citation
Tvs. Klos et al., Patellar tendon graft position after anterior cruciate ligament reconstruction - Interobserver variability on lateral radiographs, ACT ORTH SC, 70(2), 1999, pp. 180-184
Citations number
16
Categorie Soggetti
Ortopedics, Rehabilitation & Sport Medicine","da verificare
Journal title
ACTA ORTHOPAEDICA SCANDINAVICA
ISSN journal
00016470 → ACNP
Volume
70
Issue
2
Year of publication
1999
Pages
180 - 184
Database
ISI
SICI code
0001-6470(199904)70:2<180:PTGPAA>2.0.ZU;2-M
Abstract
We compared the reliability and validity of graft position measurements mad e by 4 orthopedic surgeons on intraoperative radiographs obtained using flu oroscopic control and postoperative radiographs obtained from the same 17 p atients 6 weeks after ACL reconstruction. Measurements from postoperative r adiographs varied significantly more than those from intraoperative radiogr aphs. There was little agreement between the postoperative and intraoperati ve measurements of the tibial and femoral graft position. We conclude that postoperative radiographs are not a sufficient tool for assessing graft pla cement after ACL reconstruction using patellar tendon autografts. In order to consider graft position in follow-up studies and to compare results from various surgeons, we suggest intraoperative fluoroscopy to produce radiogr aphs for accurate and reliable measurements.