Stress corrosion studies of ion implanted austenitic steel

Citation
Xl. Zhang et al., Stress corrosion studies of ion implanted austenitic steel, J MATER SCI, 34(9), 1999, pp. 2159-2162
Citations number
10
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Material Science & Engineering
Journal title
JOURNAL OF MATERIALS SCIENCE
ISSN journal
00222461 → ACNP
Volume
34
Issue
9
Year of publication
1999
Pages
2159 - 2162
Database
ISI
SICI code
0022-2461(19990501)34:9<2159:SCSOII>2.0.ZU;2-2
Abstract
Stress corrosion studies of 50 Mn18Cr4 austenitic steel implanted with 120 keV N+, 100 keV Cr+, 200 keV and 400 keV Er+ ions were carried out by const ant strain method in the nitrate solution. Surface composition and depth pr ofiles of the implanted material were measured by AES sputter etching techn ique. The results exhibit that nitrogen implantation has no significant aff ection to the stress corrosion, but the chromium and erbium implantation ha s prolonged the incubation period of the stress corrosion cracking. (C) 199 9 Kluwer Academic Publishers.