Efh. Peraza et al., Development and implementation of the k(0)-standardization and other parametric methods of INAA in Cuba. Part I, J RAD NUCL, 240(2), 1999, pp. 437-443
This paper explains chronologically the implementation of the k(0)-standard
ization and other parametric methods in Cuba. Fundamental and applied resul
ts in the determination of the most important parameters are obtained, usin
g the IBR-2 at Dubna and Triga Mark III at Mexico reactor facilities. Some
modifications in the Stoughton-Halpering convention, and its comparison wit
h the modified Westcott and Hogdahl method are presented. The application o
f the described methods at the CS-ISCTN low flux facility, using the big sa
mples techniques, is presented.