Within the DLR-Project PAREX (<(PA)under bar>rabol (R) under bar innen <(EX
)under bar>periment) it could be shown by experiments and calculations, tha
t collector efficiencies of parabolic troughs can be increased by up to 2%
by means of the use of an end reflector, which is placed at the north end o
f each trough (in case of a north-south oriented plant at the northern hemi
sphere). Calculations show that the intensity of the incident concentrated
radiation on the surface of the absorber increases by a factor of two. A fi
rst prototype of a 0,7 m(2) end reflector was tested at the DLR in the PARM
ESAN (<(PA)under bar>arbol (R) under bar innen<(MES)under bar>s<(AN)under b
ar>lage) test facility. The radiation profile around the absorber was measu
red and compared to the calculated results. A second 6,4 m(2) end reflector
was designed and built up at the LS-3 test loop at the Plataforma Solar de
Almeria (PSA).