CT reconstruction by using the MLS-ART technique and the KCD imaging system - I: Low-energy X-ray studies

Citation
Hq. Guan et al., CT reconstruction by using the MLS-ART technique and the KCD imaging system - I: Low-energy X-ray studies, IEEE MED IM, 18(4), 1999, pp. 355-358
Citations number
7
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Eletrical & Eletronics Engineeing
Journal title
IEEE TRANSACTIONS ON MEDICAL IMAGING
ISSN journal
02780062 → ACNP
Volume
18
Issue
4
Year of publication
1999
Pages
355 - 358
Database
ISI
SICI code
0278-0062(199904)18:4<355:CRBUTM>2.0.ZU;2-C
Abstract
We investigated the use of the kinestatic charge detector (KCD) combined wi th the multilevel scheme algebraic reconstruction technique (MLS-ART) for X -ray computer tomography (CT) reconstruction. The KCD offers excellent dete ctive quantum efficiency and contrast resolution. These characteristics are especially helpful for applications in which a limited number of projectio ns are used. In addition, the MLS-ART algorithm offers better contrast reso lution than does the conventional convolution backprojection (CBP) techniqu e when the number of projections is limited. Here we present images of a Ra ndo-head phantom that was reconstructed by using the KCD and MLS-ART. We al so present, for comparison, the images reconstructed by using the CBP techn ique. The combination of MLS ART and the KCD yielded satisfactory images af ter just one or two iterations.