Tj. Gruetzmacher et Rl. Bradley, Identification and control of processing variables that affect the qualityand safety of fluid milk, J FOOD PROT, 62(6), 1999, pp. 625-631
The objective of this study was to increase quality and safety of fluid mil
k by eliminating postpasteurization contamination as measured by extended s
helf life. Milk shelf life was defined as the number of days for standard p
late count to reach 20,000 CFU/ml in milk stored at 7 degrees C. Sequential
analysis of the fluid milk processing system indicated filling machine and
pasteurizer were significant sources of postpasteurization contamination.
Aseptically sampled milk from the pasteurizer outlet indicated a maximum sh
elf life of more than 30 days could be achieved. The pasteurizer can be a s
ource of contamination when inadequately cleaned or maintained. The filling
machine was a significant source of contamination. Shelf life of milk in 2
36-ml containers was reduced 20 days compared with milk sampled before the
filling machine. Carton-forming mandrels, filling heads, and airborne micro
organisms were sources of contamination within the filling machine. Elimina
ting sources of postpasteurization contamination and proper cleaning follow
ed by sanitizing with chlorine significantly increased milk shelf life in p
aperboard containers; to 20.4 days from an initial shelf life of 9 days. Ch
anging the sanitizing agent to peroxyacetic acid significantly increased mi
lk shelf life to 33.9 days, Enclosing the filling chamber and adding steril
e laminar flowing air significantly improved microbiological quality of air
inside the chamber and reduced variance among milk shelf life samples.