Stabilization of a physeal fracture using an Orthofix (R) partially-threaded Kirschner wire

Citation
Oi. Lanz et al., Stabilization of a physeal fracture using an Orthofix (R) partially-threaded Kirschner wire, VET COMP OR, 12(2), 1999, pp. 88-91
Citations number
8
Categorie Soggetti
Veterinary Medicine/Animal Health
Journal title
VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY
ISSN journal
09320814 → ACNP
Volume
12
Issue
2
Year of publication
1999
Pages
88 - 91
Database
ISI
SICI code
0932-0814(199905)12:2<88:SOAPFU>2.0.ZU;2-P
Abstract
Successful treatment of humeral condylar fractures requires accurate reduct ion and rigid internal fixation which can be difficult to achieve in toy an d/or miniature breed dogs. Stabilization of a Salter-Harris type IV physeal fracture of the numeral condyle was simplified by using Orthofix (R) parti ally-threaded Kirschner wire and provided excellent clinical results in a 1 .5 kg miniature pinscher.