A SENSOR FOR BALANCING FLUX IN CONVERTERS WITH A HIGH-FREQUENCY TRANSFORMER LINK

Citation
S. Klopper et Ja. Ferreira, A SENSOR FOR BALANCING FLUX IN CONVERTERS WITH A HIGH-FREQUENCY TRANSFORMER LINK, IEEE transactions on industry applications, 33(3), 1997, pp. 774-779
Citations number
3
Categorie Soggetti
Engineering,"Engineering, Eletrical & Electronic
ISSN journal
00939994
Volume
33
Issue
3
Year of publication
1997
Pages
774 - 779
Database
ISI
SICI code
0093-9994(1997)33:3<774:ASFBFI>2.0.ZU;2-Y
Abstract
A method is introduced for measuring a selected flux threshold below s aturation, by means of a pickup winding, The method is illustrated usi ng a block-wave oscillator and involves placing a pickup winding in a square indentation in the center leg of an E-core, Incorporating an ai r gap, a high-reluctance path is created at the area of the indentatio n, The remaining area saturates first and forces flux through the high -reluctance path, which induces a voltage on the pickup winding. The m ethod was tested experimentally, and a proposed mathematical model was used to simulate the magnetic behavior of the sensor, Experimental an d simulated results are presented and compared to verify the discussed operation, Although similar strategies have been reported previously, the significance of the sensor introduced in this paper is that detec tion takes place before saturation occurs and the sensor is integrated in the core.