AC quantized Hall resistance (QHR) measurements have been performed with an
improved probe and sample mounting system. We describe investigations of t
he structure of the R-H plateau for a range of sample currents and temperat
ures, and for different wiring configurations. We have observed R-xx minima
smaller than 0.02 x 10(-6) of R-H, an order of magnitude smaller than most
published values.