Numerical analysis of a dental implant system preloaded with a washer

Citation
A. Versluis et al., Numerical analysis of a dental implant system preloaded with a washer, INT J O M I, 14(3), 1999, pp. 337-341
Citations number
8
Categorie Soggetti
Dentistry/Oral Surgery & Medicine
Journal title
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
ISSN journal
08822786 → ACNP
Volume
14
Issue
3
Year of publication
1999
Pages
337 - 341
Database
ISI
SICI code
0882-2786(199905/06)14:3<337:NAOADI>2.0.ZU;2-7
Abstract
Gold screw loosening is a problem that frequently affects dental implants. The application of a preload has been the main means of preventing loosenin g. However, this measure has not been able to eliminate its occurrence. In this study the effect of a washer in a Branemark-type implant on the loosen ing conditions of the retaining screw was investigated using a finite eleme nt simulation. The simulation indicated that a washer may significantly inc rease the tolerance of a screw against loosening. This is accomplished by i ncreasing the tolerance of the implant against deformation. The addition of a customized washer to a dental implant system may offer a very simple and inexpensive solution for the persistent problem of screw loosening.