A BIODEGRADABLE PATCH USED AS A PERICARDIAL SUBSTITUTE AFTER CARDIAC-SURGERY - 6-MONTH AND 24-MONTH EVALUATION WITH CT

Citation
O. Duvernoy et al., A BIODEGRADABLE PATCH USED AS A PERICARDIAL SUBSTITUTE AFTER CARDIAC-SURGERY - 6-MONTH AND 24-MONTH EVALUATION WITH CT, The thoracic and cardiovascular surgeon, 43(5), 1995, pp. 271-274
Citations number
15
Categorie Soggetti
Cardiac & Cardiovascular System","Respiratory System",Surgery
ISSN journal
01716425
Volume
43
Issue
5
Year of publication
1995
Pages
271 - 274
Database
ISI
SICI code
0171-6425(1995)43:5<271:ABPUAA>2.0.ZU;2-L
Abstract
Biodegradable patches made of polyhydroxybutyrate (PHB) were recently shown to limit postoperative pericardial adhesions when inserted into the pericardium in sheep. The present study was carried out to evaluat e the presence of postoperative retrosternal adhesions after cardiac s urgery in patients operated on with the PHB patch compared with those operated on without the insertion of such a patch. 50 patients admitte d for CABG and/or valvular replacement were randomised to treatment ei ther with pericardial closure with a patch or with the pericardium lef t open. In 39 of these (19 with and 20 without a PWB patch) computeris ed tomography was carried out six and twenty-four months postoperative ly. Computerised tomography indicated a lower incidence (p < 0.05) of postoperative adhesions between the patch and the cardiac surface in t he patch group, compared with the corresponding area in the non-patch group. A reduction of patch size in 27 % (p = 0.003) was also seen.