O. Duvernoy et al., A BIODEGRADABLE PATCH USED AS A PERICARDIAL SUBSTITUTE AFTER CARDIAC-SURGERY - 6-MONTH AND 24-MONTH EVALUATION WITH CT, The thoracic and cardiovascular surgeon, 43(5), 1995, pp. 271-274
Biodegradable patches made of polyhydroxybutyrate (PHB) were recently
shown to limit postoperative pericardial adhesions when inserted into
the pericardium in sheep. The present study was carried out to evaluat
e the presence of postoperative retrosternal adhesions after cardiac s
urgery in patients operated on with the PHB patch compared with those
operated on without the insertion of such a patch. 50 patients admitte
d for CABG and/or valvular replacement were randomised to treatment ei
ther with pericardial closure with a patch or with the pericardium lef
t open. In 39 of these (19 with and 20 without a PWB patch) computeris
ed tomography was carried out six and twenty-four months postoperative
ly. Computerised tomography indicated a lower incidence (p < 0.05) of
postoperative adhesions between the patch and the cardiac surface in t
he patch group, compared with the corresponding area in the non-patch
group. A reduction of patch size in 27 % (p = 0.003) was also seen.