Fourteen correlations and four equations of state (EOS) have been used to p
redict the liquid density of 15 refrigerants. Overall, Hankinson and Thomso
n correlation [R.W. Hankinson, G.H. Thomson, AIChE J., 26 (1979) 653-663] w
ith an average of absolute percent deviation of 0.381 is the best for the p
rediction of liquid density of the refrigerants. The Chain of Rotator Group
Contribution (CORGC) equation of state [J.D. Pults, R.A. Greenkorn, K.C. C
hao, Chem. Eng. Sci., 44 (1989) 2553-2564] with an average of absolute perc
ent deviation of 1.227 is the best among the equations of state and the fou
rth in overall. (C) 1999 Elsevier Science B.V. All rights reserved.