In severe forearm injuries, the diagnosis of disruption of the interos
seous membrane is frequently delayed and sometimes missed, giving diff
iculties in the salvage of forearm stability. We studied the structure
and function of the interosseous membrane in 11 cadaver preparations,
using mechanical and histological analysis, Seven of the specimens te
sted in uniaxial tension sustained a mid-substance tear of the central
band of the membrane at a mean peak load of 1038+/-308 N. The axial s
tiffness was 190+/-44 N/mm with elongation to failure of 10.34+/-2.46
mm. These results provide criteria for the evaluation of reconstructiv
e methods. A preliminary clinical investigation of the use of ultrasou
nd suggests that this may be of value in the screening of patients wit
h complex fractures of the forearm, and for investigating the natural
history of tears of the interosseous membrane.