Treatment of a Legionella pneumophila-colonized water distribution system using copper-silver ionization and continuous chlorination

Citation
A. Biurrun et al., Treatment of a Legionella pneumophila-colonized water distribution system using copper-silver ionization and continuous chlorination, INFECT CONT, 20(6), 1999, pp. 426-428
Citations number
12
Categorie Soggetti
Envirnomentale Medicine & Public Health
Journal title
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY
ISSN journal
0899823X → ACNP
Volume
20
Issue
6
Year of publication
1999
Pages
426 - 428
Database
ISI
SICI code
0899-823X(199906)20:6<426:TOALPW>2.0.ZU;2-D
Abstract
The detection in April 1997 of a case of nosocomial legionellosis in our ho spital led to the discovery that both our hot- and cold-water circuits were heavily colonized with Legionella Pneumophila. Conventional methods for er adication of the organisms were unsuccessful, so a copper-silver (Cu-Ag) io nization system and a continuous chlorination system were installed. Five m onths later, the number of colonized sites decreased from an initial 58.3% to 16.7% (Infect Control Hosp Epidemiol 1999;20:426-428).