F. Pironti et al., Liquid-solid wetting factor in trickle-bed reactors: its determination by a physical method, CHEM ENG SC, 54(17), 1999, pp. 3793-3800
The solid-liquid wetting factor, f, was experimentally determined in a fixe
d-bed three-phase reactor with downward concurrent gas and liquid flows (tr
ickle-bed reactor). The method employed consisted of comparing the shear st
ress obtained when two phases (liquid and gas) circulated through the bed,
with that obtained at liquid-full bed conditions, maintaining the intrinsic
liquid and gas velocities constant. The shear stresses were related with p
ressure drop and liquid hold-up. In this way, a non-intrusive method can be
applied to any chemical trickle-bed reactor by only measuring pressure dro
p and liquid hold-up. Experiments were carried out in a pilot unit, where t
he flow of both phases was modified, obtaining a direct dependency off with
the flow and hold-up of liquid and f values in agreement with those report
ed by other methods. (C) 1999 Elsevier Science Ltd: All rights reserved.