S. Morales et R. Cela, Capillary electrophoresis and sample stacking in non-aqueous media for theanalysis of priority pollutant phenols, J CHROMAT A, 846(1-2), 1999, pp. 401-411
Non-aqueous capillary electrophoresis was applied to the separation of phen
ol derivatives included in the US Environmental Protection Agency list of p
riority pollutants and European Union directive 76/464/EEC concerning dange
rous substances discharged into the aquatic environment. Best results were
obtained with 60 mM ammonium acetate solution in acetonitrile-0.1 M KOH met
hanolic solution-acetic acid (74:25:1) as running buffer. A significant sen
sitivity enhancement was observed when field-amplified sample stacking in n
on-aqueous media was assayed for the study of low concentrated samples. (C)