The enhanced capabilities of a dual-column system are quickly becoming real
ized by the semiconductor industry for performing a wide range of applicati
ons on full wafer samples. A dual-column system integrates the capabilities
of an electron column for scanning electron microscopy, and a focused ion
beam (FIB) column for milling and depositing materials. An ideal dual-colum
n system is able to perform all of the functions of a single-beam system, w
hile enhancing the capabilities by operating the columns concurrently. Some
of the applications where a dual-column system has an advantage over a sin
gle-beam system include material deposition, TEM sample preparation, defect
characterization, and process control. By combining the modification capab
ilities of an FIB and the non-destructive imaging of the electron column, t
he dual-column system will become an important tool not only in the failure
analysis laboratory but also in the fabrication facility. (C) 1999 Elsevie
r Science Ltd. All rights reserved.