A spectroscopic detecting system for measuring the temperature distribution of silver breaking arc using a CCD color camera

Citation
M. Takeuchi et T. Kubono, A spectroscopic detecting system for measuring the temperature distribution of silver breaking arc using a CCD color camera, IEEE INSTR, 48(3), 1999, pp. 678-683
Citations number
12
Categorie Soggetti
Instrumentation & Measurement
Journal title
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
ISSN journal
00189456 → ACNP
Volume
48
Issue
3
Year of publication
1999
Pages
678 - 683
Database
ISI
SICI code
0018-9456(199906)48:3<678:ASDSFM>2.0.ZU;2-K
Abstract
This paper describes a spectroscopic detecting system that utilizes a CCD c olor camera to observe the distributions of two spectral intensities along the axis of an are column. Following this, the distributions of Ag I 421 mn and Ag I 547 nm spectra observed along the axis of an are column and the a re temperature calculated from the two spectra when silver contacts interru pt a circuit of de 50 V and 3.3 A are presented. The spectral intensities o f excited silver atoms are strongest near the cathode and become weaker wit h distance from the cathode contact. The temperature in the cross section o f an are column is highest in the axis of the are column. The temperature a long the axis of are column is highest near the cathode and becomes weaker with distance from the cathode. Furthermore, in this study it is clarified that CN band spectra exist near the anode contact.