A simple, rapid and reproducible-high-performance liquid chromatographic me
thod for the quantitative determination of cefepime in human plasma was dev
eloped. Ceftazidime was used as internal standard. Chromatography was perfo
rmed on a reversed-phase encapped column (Hypersil BDS C-18) The samples, a
fter protein precipitation, were eluted with a mobile phase of acetonitrile
-acetate buffer, pH 4 (2.8:97.2, v/v). The detection wavelength was 254 nm.
The limit of quantitation of cefepime was 0.5 mu g/mL and only 0.5 mt of p
lasma sample was required for the determination. The average cefepime recov
eries over a concentration range of 0.5-500 mu g/mL ranged from 98 to 104%.
Precision and accuracy did not exceed 5%. Copyright (C) 1999 John Wiley &
Sons, Ltd.