Simultaneous measurement of neutron and gamma-ray radiation levels from a TRIGA reactor core using silicon carbide semiconductor detectors

Citation
Ar. Dulloo et al., Simultaneous measurement of neutron and gamma-ray radiation levels from a TRIGA reactor core using silicon carbide semiconductor detectors, IEEE NUCL S, 46(3), 1999, pp. 275-279
Citations number
9
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
ISSN journal
00189499 → ACNP
Volume
46
Issue
3
Year of publication
1999
Part
1
Pages
275 - 279
Database
ISI
SICI code
0018-9499(199906)46:3<275:SMONAG>2.0.ZU;2-4
Abstract
The ability of a silicon carbide radiation detector to measure neutron and gamma radiation levels in a TRIGA reactor's mixed neutron/gamma field was d emonstrated. Linear responses to epicadmium neutron fluence rate (up to 3 x 10(7) cm(-2) s(-1)) and to gamma dose rate (0.6 - 234 krad-Si h(-1)) were obtained with the detector. Axial profiles of the reactor core's neutron an d gamma-ray radiation levels were successfully generated through sequential measurements along the length of the core. The SiC detector shows a high l evel of precision for both neutrons and gamma rays in high-intensity radiat ion environments - 1.9% for neutrons and better than 0.6% for gamma rays. T hese results indicate that SiC detectors are well suited for applications s uch as spent fuel monitoring where measurements in mixed neutron/gamma fiel ds are desired.