Development of a high speed X-ray tomography system for multiphase flow imaging

Citation
Ej. Morton et al., Development of a high speed X-ray tomography system for multiphase flow imaging, IEEE NUCL S, 46(3), 1999, pp. 380-384
Citations number
7
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
ISSN journal
00189499 → ACNP
Volume
46
Issue
3
Year of publication
1999
Part
1
Pages
380 - 384
Database
ISI
SICI code
0018-9499(199906)46:3<380:DOAHSX>2.0.ZU;2-E
Abstract
This paper describes a new system for quantitative measurement of multiphas e now. It is based on the use of high speed (50 frames per second) X-ray to mographic imaging. This requires a new X-ray tube concept to be implemented , together with an annular detector array and data acquisition system: A pr essurised,krypton microgap detector is being developed to give 30% quantum efficiency for detection of K-alpha radiation from the silver anode X-ray t ube. Results from simulation work are presented to justify the overall desi gn strategy selected.