Characterization method for a new diffusion mixer applicable in micro flowinjection analysis systems

Citation
Tt. Veenstra et al., Characterization method for a new diffusion mixer applicable in micro flowinjection analysis systems, J MICROM M, 9(2), 1999, pp. 199-202
Citations number
6
Categorie Soggetti
Eletrical & Eletronics Engineeing
Journal title
JOURNAL OF MICROMECHANICS AND MICROENGINEERING
ISSN journal
09601317 → ACNP
Volume
9
Issue
2
Year of publication
1999
Pages
199 - 202
Database
ISI
SICI code
0960-1317(199906)9:2<199:CMFAND>2.0.ZU;2-H
Abstract
A new mixer is designed for mixing a phenolic solution into water. The mixe r design is such that it can be easily adjusted for the controlled mixing o f a specific compound within a certain time. This paper describes the worki ng principle of the mixer as well as a suitable characterization method for the mixer. Measurement results are presented which show the correct workin g of the mixer. A quantitative measure is introduced to express the extent of mixing performed by the mixer. The characterization method allows the me asurement of the flow rate, pressure drop and extent of mixing.