Thermal contrast detected with a quantum detector

Citation
G. Paez et Ms. Scholl, Thermal contrast detected with a quantum detector, INFR PHYS T, 40(4), 1999, pp. 261-265
Citations number
8
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Optics & Acoustics
Journal title
INFRARED PHYSICS & TECHNOLOGY
ISSN journal
13504495 → ACNP
Volume
40
Issue
4
Year of publication
1999
Pages
261 - 265
Database
ISI
SICI code
1350-4495(199908)40:4<261:TCDWAQ>2.0.ZU;2-M
Abstract
We evaluate the thermal contrast detected by a quantum detector in a focal plane of an infrared instrument. The detected thermal contrast is shown to consist of two terms. The term corresponding to the temperature dependence of emissivity, previously neglected, is evaluated and shown to be a signifi cant contributing factor. For the case of a metal mirror as a source of str ay Light, ghost images, and narcissus, the error is estimated to be about 2 0%. The term in the detected contrast associated with the radiative emissio n is shown to be proportional to temperature to the power of 2, rather than 3, published previously. (C) 1999 Published by Elsevier Science B.V. All r ights reserved.